Graphic LCD Display
Text and mnemonic diagrams displaying operating modes, system parameters, and alarm signals.
Connection 10/100 BaseT
The availability of detailed information on battery runtime, load level, and technical condition indicators facilitates timely replacement, reducing the risk of downtime.
Energy-saving mode of the UPS, protected by a patent application
When quality power is supplied from the external network, the UPS operates in a mode that consumes less energy (by not utilizing some internal modules), enhancing its energy efficiency without compromising the quality of protection for connected equipment.
Battery failure notification
Advance notification of impending battery failure allows for timely preventive maintenance.
Automatic internal bypass
In case of overload or UPS failure, the load is switched to power from the electrical network.
Scalability of battery runtime
If necessary, it allows for a quick increase in backup time.
Intelligent battery management
Maximizes battery efficiency, extends its lifespan, and enhances reliability through precise intelligent charging.
Battery replacement during UPS operation
Ensures that protected equipment receives clean sine wave power during battery replacement.
Automatic restart of connected loads after UPS shutdown
Automatically starts connected equipment after network power is restored.
Battery charging with temperature compensation
Extends battery life by adjusting the charging voltage according to battery temperature.
UPS management via local network
Allows remote management of the UPS over the network.
Compatible with InfraStruXure Manager
Enables centralized management using APC InfraStruXure Manager.
SmartSlot connector
The use of control cards allows modification of the UPS's capabilities.
LED status indicators
Visual indicators quickly provide an overview of the device and power status.
Connection via serial port
Management of the UPS through the serial port.
External batteries connected via Plug-and-Play
Ensures protected equipment receives sine wave power during the connection of additional batteries to the UPS.
Converted between tower/chassis configurations for installation in equipment racks
Protects initial investments in the UPS when transitioning from a vertical UPS to rack-mounted UPS.
Hot-swappable battery replacement
Possibility of connecting an external battery pack
Management
Communication interface with PC RS-232/RJ-45/SmartSlot
Specifications
UPS Type: Double Conversion (on-line)
Application: For home, for computer
Output Power
Volt-amperes: 10000 VA
Watts: 10000 W
Input Network Parameters
Nominal Voltage: 230/400 V (3 phases)
Minimum Voltage (for operation from 220V network): 160 V
Maximum Voltage (for operation from 220V network): 275 V
Frequency: 50/60 Hz
Frequency Deviation Range: ± 20% (10 Hz)
Output Parameters
Nominal Voltage: 230 V (± 3%)
Frequency: 50/60 Hz (± 3 Hz)
Efficiency at Full Load: 94.6% (at 50% load: 95%)
Transfer Time: ms (continuous)
Battery Parameters
DC Voltage: 96 V (8x 12 V)
Charging Time: 1.5 hours
Runtime at Max Load: 3.8 min. (at 50% load: 11.5 minutes)
Ability to connect additional batteries: + (up to two sets)
Filtering and Protection
Wired (computer) network protection: + (RJ-45)
Telephone line protection: + (RJ-45)
Surge suppression: 480 J
Overload protection: +
Overvoltage protection: +
Battery deep discharge protection: +
Connectors
PC connection interface: USB
SmartSlot: 1 pc.
Input Connectors: Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH+N+G), RJ-45
Output Connectors: (1) Hard Wire 3-wire (HN + G), (6) IEC 320-C13, (4) IEC 320-C19, (3) IEC Jumpers, RJ-45
Physical Characteristics
Width: 263 mm
Height: 432 mm
Depth: 715 mm
Weight: 111.82 kg (gross: 126.82 kg)
Additional Characteristics
Topology: Double Conversion (Peak Factor 03:01)
Bypass: Internal (with automatic or manual activation)
Battery Type: Sealed lead-acid battery, maintenance-free, with gelled electrolyte: leak-proof
Emergency Power Off (EPO)
Voltage waveform type: Pure sine wave
Operation
Variable (set) input voltage range: 100-275 V (50% load) - at 230 V / 173-476 V (50% load) – at 400 V
Control Panel: Multifunctional control and management console with LCD display
Audible and visual signals with a priority system based on the severity of the event
Operating range of environmental parameters: 0-40°C
Operating range of relative humidity: 0-95%
Operating altitude range: 0-3000 meters
Storage temperature: -15...+45°C
Relative humidity during storage: 0-95%
Storage altitude: 0-15000 meters
Acoustic noise level at a distance of 1 meter from the device surface: 55.00 dB(A)
Heat dissipation in network operation mode: 1497.00 BTU/hour
Protection class: IP 20
Package includes:
UPS
Power cord
Software CD
Documentation CD
Installation guide
Temperature sensor
USB cable
Web/SNMP Management Card
```
Reviews
There are no reviews for this product.
There are no reviews for this product, be the first to leave your review.
Answers & questions
Add your question and we will answer as soon as possible.
Ask a question
Add your question and we will answer as soon as possible.
No questions about this product, be the first and ask your question.